Page 161 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 161
DOMETIC REFRIGERATOR
FITTED EQUIPMENT Manual energy selection / Automatic energy selection /
automatic ignition (RM 8xx1/ automatic ignition (RM 8xx5/
RML9xx1) MES RML9xx5) AES
1 2 34 678 1 2 34 5 678
Fig. 8 Fig. 9
1 - Power ON/OFF switch 1 - Power ON/OFF switch
2 - Energy selector button 230V ~ 2 - Energy selector button 230V ~
3 - Energy selector button GAS 3 - Energy selector button GAS
4 - Energy selector button 12V = 4 - Energy selector button 12V =
6 - Temperature level selection 5 - Selector button “AUTOMATIC”
7 - Temperature level display 6 - Temperature level selection
8 - Indicator LED failure / Reset button 7 - Temperature level display
GAS FAILURE
8 - Indicator LED failure / Reset button
Switching ON/OFF GAS FAILURE
• Switch ON by pressing button (1), 2s
Switching ON/OFF
• Switch OFF by pressing button (1), > 2s • Switch ON by pressing button (1), 2s
230V AC operation • Switch OFF by pressing button (1), > 2s
• Select “Mains voltage” by pressing button (2)
Manual operation
• Set temperature step by pressing button (6) • Select energy source with buttons (2,3,4)
12V DC operation (vehicle’s battery) • Set temperature step by pressing button (6)
• Select “Battery voltage” by pressing Automatic operation
button (4)
• C hange over to “Automatic” with button (5)
• Set temperature step by pressing button (6) Automatical energy selection (if available)
Sequence of priority:
Gas operation 1.) Solar (12V -)
• Select “Gas” by pressing button (3) 2.) 230V ~
3.) 12V -
• Set temperature step by pressing button (6) 4.) Liquid gas
• Set temperature step by pressing button (6)
148