ALDE BOILER TROUBLESHOOTING
Trouble-Shooting • C heck that hot water boost is not activated FITTED EQUIPMENT
on the Alde control panel.
The Alde control panel will display any error
messages. See the Operating and Installation • U se gas and electric heating.
Instructions supplied separately.
• C heck that vents in the furniture are not
The system is completely dead, the obstructed.
control panel is blank
• Check the condition of the heat transfer fluid.
• C heck the 20 mm T3.15 Amp glass fuse in
the boiler. This is located under the lid of the • M ost vehicles will reach a comfortable
black plastic service hatch, in a green plastic temperature within an hour, in non-extreme
fuse holder. conditions.
• C heck the 12v supply to the boiler, it should If problems persist, please contact Alde, or
be above 12v. your dealer or installer.
• C heck the 12v cable is plugged into the WARRANTY
boiler. Check the cable is plugged into the
Alde control panel. Alde undertakes to rectify any manufacturing
defect or early component failure through
The boiler will not ignite on gas normal use that occurs within 12 months of
the installation date.
• C heck the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas. If your Alde boiler develops a fault, your first
action should be to contact your dealer or
• T he system may not need to use gas installer, as they will be familiar with your
heating, if also using electric heating. installation and vehicle, and how to make a
claim under warranty.
• T he fluids in the boiler may already be at
operating temperature. Alde International (UK) Ltd Huxley Close Park
Farm South Wellingborough Northamptonshire
The boiler will not heat on 230 V electric NN8 6AB
• C heck that any 230v isolator switches are on Tel. 01933 677765
(they will often have an LED indicator). www.alde.co.uk
• C heck the 230v supply to the vehicle.
• T he fluids in the boiler may already be at
operating temperature.
No hot water
• C heck that hot water ignore is not activated
on the Alde control panel.
• C heck that constant pumping is not
activated on the Alde control panel.
• C heck for other conflicting settings on the
Alde control panel.
• C heck the freshwater supply and water
pump.
No central heating
• B leed the system of air.
• C heck the fluid level in the expansion tank.
• C heck that the circulation pump is
responding.