ELECTRICAL SYSTEM

The electrical system                               On departure from the campsite                       SERVICES

General Information                                 • S witch off supply from the site, disconnect
                                                      the cable at both ends.
It is strongly advised that the mains installation
is inspected periodically to ensure safe            • S witch off RCD.
use. The IET (BS7671) wiring regulations
recommend that mains installations in                Note: Never use a mains supply lead whilst
motorhomes are re-inspected every 3 years            coiled. Always uncoil the full length before
or annually if the van is used frequently. The       connecting to the supply and remember to
National Caravan Council lists the qualifications    protect the cable from traffic.
necessary to perform this inspection, but an
NICEIC approved contractor is probably the           ! WARNING: Current consumption in the
first choice.
                                                     motorhome must not exceed 16 amps or
On arrival at the campsite                           the pitch permitted maximum if this is less
                                                     than 16 amps.
• Check the suitability of the supply,
  is it AC or DC, is the voltage and frequency      Overseas connection
  correct.
                                                    • Connection to a mains voltage overseas
• Ensure that there is a proper earth                requires particular attention.
  (3 pin socket outlet).
                                                    • Overseas supplies can be of
• If in doubt consult site staff.                    reverse polarity.

• Make sure that the supply from the site is       • R everse polarity results in equipment not
  switched off.                                       necessarily being isolated when turned off,
                                                      reverse polarity indicator on the PSU will light
• Make sure that the charger switch on the           in the event of reverse polarity.
  PSU is switched off.
                                                    • T he only sure way to make equipment safe is
• Lift the cover on the electricity inlet on the     to unplug it.
  motorhome, and insert the connector on the
  flexible supply cable.                            • It is useful to have a means of checking
                                                      polarity when overseas.
• At the site supply point, connect the other
  end of the supply cable to this using the         • If it can be achieved then connect live to live,
  socket provided.                                    and neutral to neutral to achieve full electrical
                                                      protection.
• Switch on the main switch at the site
  supply point.                                      ! WARNING: Never allow modifications

 Note: It is good practice to test the RCD           of electrical or LPG systems and appliances
 (Residual Current Device) in the PSU before         except by qualified persons.
 switching on. There is a test button on the
 RCD to test the lever, put the lever in the up
 position (on) before testing.

Note: As with the RCD it is good practice
to check the Miniture Circuit Breaker (MCB)
in the PSU. Switch all to the on position
(lever up). If any do not stay up then there
is a fault.