ELECTRICAL SYSTEM
The electrical system On departure from the campsite SERVICES
General Information • S witch off supply from the site, disconnect
the cable at both ends.
It is strongly advised that the mains installation
is inspected periodically to ensure safe • S witch off RCD.
use. The IET (BS7671) wiring regulations
recommend that mains installations in Note: Never use a mains supply lead whilst
motorhomes are re-inspected every 3 years coiled. Always uncoil the full length before
or annually if the van is used frequently. The connecting to the supply and remember to
National Caravan Council lists the qualifications protect the cable from traffic.
necessary to perform this inspection, but an
NICEIC approved contractor is probably the ! WARNING: Current consumption in the
first choice.
motorhome must not exceed 16 amps or
On arrival at the campsite the pitch permitted maximum if this is less
than 16 amps.
• Check the suitability of the supply,
is it AC or DC, is the voltage and frequency Overseas connection
correct.
• Connection to a mains voltage overseas
• Ensure that there is a proper earth requires particular attention.
(3 pin socket outlet).
• Overseas supplies can be of
• If in doubt consult site staff. reverse polarity.
• Make sure that the supply from the site is • R everse polarity results in equipment not
switched off. necessarily being isolated when turned off,
reverse polarity indicator on the PSU will light
• Make sure that the charger switch on the in the event of reverse polarity.
PSU is switched off.
• T he only sure way to make equipment safe is
• Lift the cover on the electricity inlet on the to unplug it.
motorhome, and insert the connector on the
flexible supply cable. • It is useful to have a means of checking
polarity when overseas.
• At the site supply point, connect the other
end of the supply cable to this using the • If it can be achieved then connect live to live,
socket provided. and neutral to neutral to achieve full electrical
protection.
• Switch on the main switch at the site
supply point. ! WARNING: Never allow modifications
Note: It is good practice to test the RCD of electrical or LPG systems and appliances
(Residual Current Device) in the PSU before except by qualified persons.
switching on. There is a test button on the
RCD to test the lever, put the lever in the up
position (on) before testing.
Note: As with the RCD it is good practice
to check the Miniture Circuit Breaker (MCB)
in the PSU. Switch all to the on position
(lever up). If any do not stay up then there
is a fault.
67