TRUMA COMBI 4E/6E BOILER
FITTED EQUIPMENT Truma Combi 4E/6E If more output is required (e.g. heating up
or low outside temperatures) gas or mixed
Function description operation should be selected so that enough
heating power is always available.
The liquid gas heater Combi E is a warm-air
heater with integrated hot water boiler (10 liter With mixed operation, 230 V electrical
volume). The burner operates fan-supported, operation is preferred if the power
which ensures trouble-free function even requirement is low (e.g. for maintaining the
when on the move. The unit also has heating room temperature). The gas burner is not
elements for electrical operation. enabled until the power requirement is higher,
and is the first to switch off during heat-up
In winter operation the heater can be used to operations.
heat the room and simultaneously warm water.
If only warm water is required, select summer Summer operation (boiler operation only)
operation.
Gas operation or 230 V electrical operation
3 different options are available for operating is used for hot water preparation. The water
the unit. temperature can be set to 40 °C or 60 °C.
• gas operation only Propane / Butane for With gas operation the water is heated at
autonomous use the lowest burner setting. Once the water
temperature is reached, the burner switches
• electrical operation only 230 V for stationary off.
use on camp sites
Depending on the fuse protection at the
• c ombined gas and electrical operation camping site, power of 900 W (3.9 A) or
(winter mode only) 1800 W (7.8 A) can be manually selected for
electrical operation.
Winter operation
Mixed operation is not possible. With this
In winter operation, the unit automatically setting the unit automatically selects electrical
selects the required power setting according operation. The gas burner is not enabled.
to the temperature difference between the
temperature set on the control panel and the Repairs may only be carried out by
current room temperature. When the boiler an expert
is filled, the water is automatically heated as
well. The water temperature depends on the Guarantee claims, warranty claims and
selected operational mode and the heater acceptance of liability will be ruled out in the
output. event of the following:
All 3 energy selection options can be used for – m odifications to the unit
winter deployment. (including accessories),
With gas operation the unit automatically – modifications to the exhaust duct and
selects the output level that is required. the cowl,
Depending on the fuse protection at the – failure to use original Truma parts as
camping site, power of 900 W (3.9 A) or replacement parts and accessories,
1800 W (7.8 A) can be manually selected for
electrical operation. – failure to follow the installation and operating
instructions.
It also becomes illegal to use the appliance,
and in some countries this even makes it illegal
to use the vehicle.
During the initial operation of a brand new
appliance (or after it has not been used for
some time), a slight amount of fumes and