Page 133 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 133

TRUMA COMBI 4E/6E BOILER

FITTED EQUIPMENT  Technical data                               Current input at 12 V
                                                               heater +boiler
                  Determined in accordance with EN 624 or
                  Truma test conditions                        Combi 4 E: Short-term max. 5.6 A (average
                                                               power consumption 1.1 A)
                  Device category                              Combi 6 E: Short-term max. 5.6 A (average
                                                               power consumption 1.3 A)
                  I3 B/P in accordance with EN 437             Heating up of boiler: 0.4 A
                  Type of gas                                  Stand-by: 0.001 A
                  Liquid gas (propane/butane)                  Heating element FrostControl (optional):
                                                               maximum 0.4 A
                  Operating pressure
                  30mbar (see type plate)

                  Water contents
                  10 litres

                  Heating up time from approx 15OC to 60OC
                  Boiler approx 20 minutes (measure according
                  to EN15033)
                  Heater + boiler approx 80 min

                  Water pressure
                  max 2.8 bar

                  Rated thermal output
                  (automatic output levels)

                  Gas operation
                  Combi 4 E: 2000 W / 4000 W
                  Combi 6 E: 2000 W / 4000 W / 6000W

                  Electrical operation
                  Combi 4 E / Combi 6 E: 900 W / 1800 W

                  Mixed operation (gas and electrical)
                  Combi 4 E: max. 3800 W
                  Combi 6 E: max. 5800 W

                  Gas consumption

                  Combi 4 E: 160-320 g/h
                  Combi 6 E: 160-480 g/h

                  Readiness-heat power requirement Combi 4 E
                  / Combi 6 E:
                  Gas operation 5.2 g/h

                  Air delivery volume
                  (free-blowing without hot-air pipe)

                  Combi 4 E:
                  with 3 hot-air outlets max. 249 m3/h
                  with 4 hot-air outlets max. 287 m3/h

                  Combi 6 E:
                  w ith 4 hot-air outlets max. 287 m3/h