Page 133 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 133
TRUMA COMBI 4E/6E BOILER
FITTED EQUIPMENT Technical data Current input at 12 V
heater +boiler
Determined in accordance with EN 624 or
Truma test conditions Combi 4 E: Short-term max. 5.6 A (average
power consumption 1.1 A)
Device category Combi 6 E: Short-term max. 5.6 A (average
power consumption 1.3 A)
I3 B/P in accordance with EN 437 Heating up of boiler: 0.4 A
Type of gas Stand-by: 0.001 A
Liquid gas (propane/butane) Heating element FrostControl (optional):
maximum 0.4 A
Operating pressure
30mbar (see type plate)
Water contents
10 litres
Heating up time from approx 15OC to 60OC
Boiler approx 20 minutes (measure according
to EN15033)
Heater + boiler approx 80 min
Water pressure
max 2.8 bar
Rated thermal output
(automatic output levels)
Gas operation
Combi 4 E: 2000 W / 4000 W
Combi 6 E: 2000 W / 4000 W / 6000W
Electrical operation
Combi 4 E / Combi 6 E: 900 W / 1800 W
Mixed operation (gas and electrical)
Combi 4 E: max. 3800 W
Combi 6 E: max. 5800 W
Gas consumption
Combi 4 E: 160-320 g/h
Combi 6 E: 160-480 g/h
Readiness-heat power requirement Combi 4 E
/ Combi 6 E:
Gas operation 5.2 g/h
Air delivery volume
(free-blowing without hot-air pipe)
Combi 4 E:
with 3 hot-air outlets max. 249 m3/h
with 4 hot-air outlets max. 287 m3/h
Combi 6 E:
w ith 4 hot-air outlets max. 287 m3/h
120