i. H ot Water Ignore. Volume bar empty.            What’s Activated Menu                               FITTED EQUIPMENT
  No attempt is made to heat hot water              Press the A button to access the What’s
  specifically. This saves energy when the          Activated Menu. This screen shows any
  freshwater is drained down.                       functions that are activated and allows direct
                                                    access to that function by pressing its button.
ii. H ot Water Normal. Volume bar half-full. Hot   NB: The A button is not displayed if no
  water is heated to greater than 50°C. NB: If      functions are activated.
  Circulation Pump is set to Continuous, this
  option will not be available.                      Note: Not all Alde functions are relevant to a
                                                     motorhome installation, (activated functions
iii. H ot Water Boost. Volume bar full. Central     are shown below)
   heating circulation is disabled for 30 mins.
   Hot water is heated to greater than 65°C.        Activated Functions
   After 30 mins the system reverts to Hot
   Water Normal.                                                        Night Mode is enabled, but
                                                                        may or may not be active,
iv. Adjust by pressing Plus or Minus button.                            depending on the time and
                                                                        day.
Electric Heating
                                                                        Delayed Start/Cycle is
Check that 230v supply is displayed on the                              enabled, but may or may not
Standby Screen. The Alde boiler is hard wired                           be active, depending on the
to use power economically and there are times                           time and day.
when it may use no power at all, even if set to
3kW.                                                                    Alde Smart-Control or
                                                                        daisy-chained, third party
i. S elect Off, 1, 2 or 3 kW electric heating.                         control panel is enabled. This
  More power equals better performance, but                             includes the Swift Command
  may be restricted by the current (amps) limit                         system. Ensure this feature is
  on the electric hook-up.                                              enabled.

ii. Adjust by pressing Plus or Minus button.                            Circulation Pump is set to
                                                                        Continuous. NB: This will
Max current draw from 230 V supply is 4.5                               reduce the hot water supply.
A on 1 kW, 9 A on 2 kW, 14 A on 3 kW. If
the electric supply has unstable voltage, the
amperage will also fluctuate.

Gas Heating

The Alde boiler is hard wired to use power
economically. The gas burner has two stages,
shifting dynamically between low or full flame.
There are times when it may use no power at
all, even if gas heating is selected.

i. P ress the Flame button to select gas heating.
  Green is on, blue is off.

Use both gas and electric heating for best
performance.