Page 139 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 139

FITTED EQUIPMENTALDE CONTROL PANEL                                   Navigation Arrows

                                   Day Mode is enabled, but          T here are four screens in the
                                   may or may not be active,         Settings Menu. The up/down
                                   depending on the time and         arrows allow you to navigate
                                   day.                              between them.

                                   Load Monitor is enabled and       Night Mode (requires Clock to
                                   an amp limit is set.              be set)
                                   (model specific)
                                                                     A llows you to programme the
               Settings Menu                                         boiler to automatically change
               Press the Tool Button to access the Settings          and select settings at night. Set
               Menu from the Main Menu. Lower level                  a start and stop time for the
               functions can be accessed by from these               night-time period. Set a day of the
               screens by pressing the buttons. NB: If a             week, or “All” for the same daily
               function is not available its button is greyed        programme. You can also define:
               out.
                                                                     • Desired room temperature
                              To return to the Main Menu, press
                              the MENU button.                       • Invert Standby Screen

                               Delayed Start/Cycle (requires         • Hot water ignore
                               Clock to be set)
                                                                     •Temperature sensor (if discrete
                               A llows you to programme the          room temperature sensors are
                               boiler to start at a specified time    connected)
                               and day, weekly. It will provide
                               heating using the last saved          • AC Quiet Mode (if Truma Aventa
                               settings for 24 hours, before           Comfort air-conditioning unit is
                               automatically shutting down             connected)
                               again. This is recommended for
                               airing the vehicle over winter if     Day Mode (requires Clock to
                               stored locally and hooked up          be set)
                               to 230 V power. Once Delayed
                               Start/Cycle is enabled, the system    A llows you to programme the
                               should be shut down by pressing       boiler to automatically change and
                               the Power button.                     select settings during the day.
                                                                     Set a start and stop time for the
                               C lock                               day-time period. Set a day of the
                               The clock must be set for            week, or “All” for the same daily
                               programmable functions to             programme. You can also define:
                               activate at the correct time/day. If
                               12 V power is lost, the clock will    • Desired room temperature
                               reset.
                                                                     • Hot water ignore
               TiP! The optional Alde 3010-414 battery
                     backup uses two AA batteries and allows         Temperature Offset
                     the clock memory to be stored even if
                     12 V power is lost.                             R ecalibrate the room temperature
                                                                     displayed by the control panel in
126                                                                  0.5 °C increments. If an outdoor
                                                                     temperature sensor is connected,
                                                                     this can also be recalibrated.

                                                                     Return

                                                                     Return to the previous menu.
   134   135   136   137   138   139   140   141   142   143   144