Page 143 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 143
ALDE CONTROL PANEL
FITTED EQUIPMENT Fig 5 Setup Standby Screen for bedtime
The following options are shown as standard. The backlight on the Standby Screen can be
Tick the box to install: disturbing if the control panel is visible from
• Alde Smart Control, or third party control your bed. It can be inverted for white text on
black background.
panel (connected to JP3 on Alde control
panel) This feature must be enabled to allow i. Press Tool button to access the Settings
Swift Command system to control ALDE Menu (bottom right in Main Menu).
system.
ii. Press down arrow, until Backlight button is
• O ptional 12V circulation pump in expansion displayed.
tank (connected at X4 on boiler)
iii. Press Backlight button, select Invert to
• Load Monitor (connected to X5 on boiler) proceed.
• 12V inline circulation pump with manual Setup Antimicrobial function
5-speed dial
To actively kill Legionella, setup the
• Remote controlled 12V inline circulation Antimicrobial function. At 2:00 every night,
pump the hot water will be heated to over 65°C
for 30 mins. This further reduces the risk of
• 230V inline circulation pump Legionella.
5. Setup i. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
How you set up your system will depend on
what accessories are installed and your user ii. Press Clock button, set the time and day.
preferences. To get you started, here’s how to Press Return.
setup some of the more common features.
iii. Press down arrow, until Antimicrobial button
Restore default factory settings is displayed.
Before using the system for the first time, iv. Press Antimicrobial button to proceed.
restore default factory settings. Your control
panel may have been tested by the dealer or
installer, and some settings may have been
changed unintentionally.
i. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
ii. Press down arrow, until Reset button is
displayed.
iii. Press the Reset button to proceed
130