Page 140 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 140

Prioritise                            Pump Manual For the 12V inline                 FITTED EQUIPMENT

                Select whether to prioritise gas     12 V.        circulation pump with
                heating or electric heating, when
                using both. Less demand will be                    manual 5-speed dial.
                placed on the non-prioritised fuel.
                                                      P ump       For the remote-controlled
TiP! If you’re hooked up to a site with a flat       Remote 12 V  12 V inline circulation
      rate 230 V supply, but still want the extra                  pump. Pump speed can
      performance from gas heating, prioritise        Optional     also be set. Speed 2 is
      electric heating to save money on gas.          Pump 12 V.   recommended. Speed 4–5
                                                                   should only be used prior
                Button Sound                                       to bleeding the system
                                                                   of air.
                Bleep when a button is pressed.
                                                                   For the optional 12V
                Backlight                                          circulation pump in the
                                                                   expansion tank.
                T he brightness of the Standby
                Screen can be adjusted from 1–3.      Pump 230 V. For the 230V inline
                The display mode of the Standby                              circulation pump
                Screen can also be set.
                                                      Auto.       Automatically selects the
	Dark. The Standby Screen is deactivated,
  the control panel may appear dormant                             230V pump when a 230V
  except for the power LED. Pressing the
  screen will activate the Standby Screen for                      supply is detected, or
  30 secs. Suited for use in dark/night-time
  conditions.                                                      the optional 12V pump

	Bright. The Standby Screen shows dark                            when only 12V supply is
   characters on a light background. Suited for
   use in bright/day-time conditions.                              available.

   Invert. The Standby Screen shows light             Pump mode can also be set.
   characters on a dark background. Suited for
   low light conditions.                              Cont. The pump is continuously active. This
                                                      will reduce the hot water supply. For testing
                Antimicrobial (requires Clock         the circulation pump in the summer, if room
                to be set)                            temperature exceeds 30°C.

                H ot Water Boost will automatically  Thermo. The pump is controlled by the room
                activate at 02:00 every morning.      thermostat.
                This further reduces the risk of
                Legionella bacteria.                                  External Switch

                Circulation Pump                              A llows you to use a third party,
                                                              external switch to start up and
                S elect which circulation pump               shutdown the boiler. When the
                to use for the central heating,               external switch starts the boiler,
                depending on what pumps are                   it will provide heating using the
                installed. (your motorhome is                 last saved settings. Once External
                fitted with ‘pump manual 12V’).               Switch is enabled, the system
                                                              should be shut down by pressing
                                                              the Power button. The external
                                                              switch then takes control of the
                                                              boiler.

                                                                                                     127