ALDE CONTROL PANEL

FITTED EQUIPMENT  Ext. When a circuit is made at X18 on the
                  boiler, the boiler is started. When the circuit
                  is broken, the boiler shuts down. For use          Error Log
                  with a third party rocker or toggle switch,
                  or compatible telematics systems. NB: The          Press the Warning button to access the Error
                  Alde 3010-219 adaptor lead is available for        Log from the Service Menu. The most recent
                  connecting an external switch.                     20 error messages are displayed. To verify an
                                                                     error message, remove the system from the
                  230V. When 230V is detected, the boiler           12V and 230V supply. Wait 10 secs before
                  is started. When 230V supply is lost, the          restoring 12V and 230V power to the system.
                  boiler shuts down. No additional accessories
                  required.

                  Off. External Switch is disabled.

                  TiP! H iring out a vehicle? Your customers can
                        operate the central heating/hot water
                        with a convenient wall switch, whilst
                        the control panel is fitted in a locked
                        maintenance cupboard with a discrete
                        room temperature sensor. On-off, no
                        hassles.

                                  Language

                                  Select English, French or German
                                  language. NB: The Service Menu
                                  is English language only.

                                  Load Monitor

                                  If an Alde 3010-246 load monitor
                                  is installed, this allows you to
                                  set an amp limit from 5–17 A
                                  for the vehicle’s 230V power. If
                                  the current drawn by the vehicle
                                  exceeds the amp limit, the boiler
                                  will automatically reduce power.

                  	This helps avoid tripping the
                                  circuit breakers on the electric
                                  hook up. The load monitor can be
                                  disabled by selecting “Off”.

                  Settings Menu

                  Press the Tool Button to access the Settings
                  Menu from the Main Menu. Lower level
                  functions can be accessed by from these
                  screens by pressing the buttons. NB: If a
                  function is not available its button is greyed
                  out.