smell may be noticed for a short while. ! WARNING: Care should be taken to FITTED EQUIPMENT
It is a good idea to heat the device up several
times in summer operation (60 °C) and to ensure adequate ventilation of the flue at all
make sure that the area is well ventilated. times. It is inadvisable to inhale exhaust fumes.
Heat-sensitive objects such as spray cans For operating on gas turn on gas cylinder and
or flammable liquids may not be stored in open the shut off valve at the manifold.
the same compartment where the heater is
installed because, under certain conditions, For operating on electric operate the heater
this area may be subject to elevated / heating system heater switch on the power
temperatures. supply unit. See page 72.
Important operating notes Summer operation (boiler operation only)
The integrity and tight fit of the exhaust gas Mixed operation (gas and electrical) is not
double duct must be checked regularly, possible in summer mode. With this setting the
particularly at the end of long trips. Also check unit automatically selects electrical operation
the mounting of the appliance and the cowl. with a preselected power setting of 900 W or
1800 W.
Following a blow-back (misfire) always have
the exhaust gas system checked by an expert! Winter operation
Always keep the cowl for the exhaust duct and Heating with water temperature
combustion air intake free of contamination monitoring
(slush, ice, leaves etc.). The device automatically selects the
required power setting in accordance with
The hot air outlets and the recirculated air the temperature difference between the
intake openings must be free so that the unit temperature selected on the control panel
does not overheat. The integrated temperature and the current room temperature. When the
limiter blocks the gas supply when the unit room temperature selected on the control
becomes too hot. panel is reached, the heater switches back to
the smallest setting and heats the water to 60
Operating Instructions °C. Once the water temperature is reached,
the heater switches off and the yellow LED (p)
Always observe the operating instructions and goes out. The warm air fan can continue to run
“Important operating notes” prior to starting! in order to cool the unit (after-run).
The vehicle owner is responsible for the
correct operation of the appliance. Heating without water temperature
monitoring
Before using for the first time, it is essential to The device automatically selects the
flush the entire water supply system through required power setting in accordance with
with clean water. If the heater is not being the temperature difference between the
used, always drain the water contents if there temperature selected on the control panel and
is a risk of frost. There shall be no claims under the current room temperature. Once the room
guarantee for damage caused by frost! temperature selected on the control panel has
been reached, the heater switches off. The
Taking into operation warm air fan continues to run at slow speed
until the outgoing air temperature (on the unit)
Heating is possible without restrictions with has fallen to 40°C or less.
gas, electrical and mixed operation, with or If the boiler is filled, the water will automatically
without water. be heated at the same time.
Check to make sure the cowl is unobstructed.
Be sure to remove any covers that may be
present.