Page 54 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 54

Pressing the Test/Mode button will also test                                                          SAFETY AND SECURITY
the power pack, sounder and circuitry of
the alarm. The unit will sound and the alarm      Note: We suggest the use of an incense
                                                  stick or cigarette as the way in which
LED below will illuminate red. You should         these products burn produces a readable
perform this test once per week.                  localised amount of CO. A readable level
                                                  of carbon monoxide will not be given off
Peak Level Reading feature.                       by other sources of smoke, for example an
                                                  extinguished candle or match.
The alarm will record the highest reading of
CO that it has detected in the last 4 weeks.
This information is useful if your alarm has
sounded so you can see the highest level of
CO detected during that time. It is also useful
to check periodically to see if a readable level
of CO has been detected for a short time, but
not long enough to trigger a full alarm. The
peak level reading is shown briefly every time
you press the Test/Mode button and will look
something like the image below.

 Note: It is possible and quite normal for the    Step 1: If the alarm is wall mounted unhook it
 peak level to remain at 0ppm, i.e. this simply             from the fixing screws.
 means that the alarm has not detected any
 CO in the last 4 weeks.                          Step 2: H old the Test/Mode button down
                                                            until the spanner icon appears in the
The Peak Level reading will be reset to 0ppm                bottom left hand corner of the screen
whenever a Sensor Test is carried out. (See                 and the bar graph ‘scans’ from left
the next section for Sensor Test).                          to right. This indicates the alarm is in
                                                            sensor test mode where the sampling
Sensor Testing                                              rate of the sensor has increased and
                                                            the alarm can be tested using a known
 ! CAUTION: Sensor testing should only                      source of CO.

 be performed by a responsible adult.             Step 3: Light an incense stick or cigarette
 This test should only be performed once a                  using a match or lighter. Extinguish the
 month. Excessive testing will shorten the life             lighter, or put out the match and place
 of the power pack.                                         it into a dish of water.

                                                  Step 4: Hold the incense stick or burning          41
                                                            cigarette 15cm (6 inches) below the
                                                            detector, so that the smoke goes
                                                            into the holes at the bottom of the
                                                            detector. As the smoke gets into the
                                                            alarm the display will show the amount
                                                            of CO being detected. When the level
                                                            of CO in the sensor reaches 50ppm
                                                            the alarm will sound a single alarm
                                                            cycle, this confirms that the sensor is
                                                            working correctly and is the end of the
                                                            sensor test. The alarm will return to
                                                            normal standby mode.
   49   50   51   52   53   54   55   56   57   58   59