WATER FAULTS

SERVICES  Water           Cause                         Remedy
                          Freshwater tank empty         Check
           Fault          Pump wired in reverse         Check wiring, refer to pump manufacturers
           Water not                                    instructions
           flowing from   Pipe inlet or outlet pipe     Check connections
           any tap when   disconnected
           operated but   Pump pipes restricted         Check pipes run
           pump runs      by kinking
                          Blockage in pump inlet or     Check, starting inside freshwater tank
           Pump does      outlet pipe
           not run        Blocked pump filter           Dismantle and clean filter. See pump
                                                        manufactures instructions.
           Water flows
           from cold tap  Air leak in suction line      Check condition of pipe and pipe joints
           but not from   to pump                       between the water tank and the pump.
           hot            Frozen pipes
                          Pump incorrectly wired        Refer to pump manufacturers instructions
                          Pump fuse blown               Check wiring connection and then replace with
                                                        fuse of correct rating
                          Battery disconnected          Check connections
                          Pump seized or overheated     Refer to pump manufacturers servicing
                                                        instructions
                          Pressure pump sensing         Refer to pump manufacturers servicing
                          switch may have failed        instructions
                          Contacts may be faulty        Check contacts in plug and socket are clean
                                                        and making contact
                          Wiring connections may        Check wiring connections
                          be faulty
                          Blockage in hot pipeline      Disconnect pipes and inspect
                          Heater inlet or outlet pipes  Check and re-route if necessary.
                          kinked preventing flow
                          Hot tap failed or blocked     Disconnect and inspect
                          Heater non-return valve       Seek service attention
                          jammed