WATER FAULTS
SERVICES Water Cause Remedy
Freshwater tank empty Check
Fault Pump wired in reverse Check wiring, refer to pump manufacturers
Water not instructions
flowing from Pipe inlet or outlet pipe Check connections
any tap when disconnected
operated but Pump pipes restricted Check pipes run
pump runs by kinking
Blockage in pump inlet or Check, starting inside freshwater tank
Pump does outlet pipe
not run Blocked pump filter Dismantle and clean filter. See pump
manufactures instructions.
Water flows
from cold tap Air leak in suction line Check condition of pipe and pipe joints
but not from to pump between the water tank and the pump.
hot Frozen pipes
Pump incorrectly wired Refer to pump manufacturers instructions
Pump fuse blown Check wiring connection and then replace with
fuse of correct rating
Battery disconnected Check connections
Pump seized or overheated Refer to pump manufacturers servicing
instructions
Pressure pump sensing Refer to pump manufacturers servicing
switch may have failed instructions
Contacts may be faulty Check contacts in plug and socket are clean
and making contact
Wiring connections may Check wiring connections
be faulty
Blockage in hot pipeline Disconnect pipes and inspect
Heater inlet or outlet pipes Check and re-route if necessary.
kinked preventing flow
Hot tap failed or blocked Disconnect and inspect
Heater non-return valve Seek service attention
jammed