DOMETIC REFRIGERATOR

FITTED EQUIPMENT  Operation with on-board
                  12 v power supply

                  Indicator            Fault                 Remedy

                  (2) and (8)          230 V mode:           Check mains power connection, mains voltage,
                                       "230V" not availa-    fuse
                  flashing and acous-  ble or voltage too
                  tic signal 20s       low

                  (4) and (8)          12 V mode:            Check 12V connection, on-board battery, fuse
                                       "12V" not available
                  flashing and acous-  or voltage too low
                  tic signal 20s

                  (3) and (8)          Gas mode:             Check gas supply (gas bottle, gas valve)
                                       Flame not ignited     Press the (8) button after clearing the fault
                  flashing and acous-
                  tic signal 20s

                  Acoustic signal,     Interior lighting is  Close door, check door contact
                  15s at two minute    switched on
                  intervals

                  (2) and (7)          230 V mode:           Arrange replacement of 230V heating element,
                                       230V heating ele-     contact Customer Service
                  flashing and acous-  ment defective
                  tic signal 20s

                  (4) and (7)          12 V mode:            Arrange replacement of 12V heating element,
                                       12V heating ele-      contact Customer Service
                  flashing and acous-  ment defective
                  tic signal 20s

                  (7)                  Temperature sensor    Contact Customer Service
                                       without contact or
                  flashing and acous-  defective
                  tic signal 20s

                  (3) and (7)          Burner defective      Check burner, burner nozzles, if
                                       or cooling unit       necessary contact Customer Service and
                  flashing and acous-  defective             arrange replacement
                  tic signal 20s

162