Page 175 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 175
DOMETIC REFRIGERATOR
FITTED EQUIPMENT Operation with on-board
12 v power supply
Indicator Fault Remedy
(2) and (8) 230 V mode: Check mains power connection, mains voltage,
"230V" not availa- fuse
flashing and acous- ble or voltage too
tic signal 20s low
(4) and (8) 12 V mode: Check 12V connection, on-board battery, fuse
"12V" not available
flashing and acous- or voltage too low
tic signal 20s
(3) and (8) Gas mode: Check gas supply (gas bottle, gas valve)
Flame not ignited Press the (8) button after clearing the fault
flashing and acous-
tic signal 20s
Acoustic signal, Interior lighting is Close door, check door contact
15s at two minute switched on
intervals
(2) and (7) 230 V mode: Arrange replacement of 230V heating element,
230V heating ele- contact Customer Service
flashing and acous- ment defective
tic signal 20s
(4) and (7) 12 V mode: Arrange replacement of 12V heating element,
12V heating ele- contact Customer Service
flashing and acous- ment defective
tic signal 20s
(7) Temperature sensor Contact Customer Service
without contact or
flashing and acous- defective
tic signal 20s
(3) and (7) Burner defective Check burner, burner nozzles, if
or cooling unit necessary contact Customer Service and
flashing and acous- defective arrange replacement
tic signal 20s
162