THETFORD CASSETTE TOILET TROUBLESHOOTING

Cassette toilet                                                                                       FITTED EQUIPMENT
fault finding

Fault           Remedy
Bowl does
not drain       DO NOT REMOVE CASSETTE. While inside the motorhome turn flush knob
when toilet is  anti-clockwise to open valve blade and leave it in the open position. Open
flushed.        access door on side of motorhome. Rotate pour-out spout outward. Place
Cassette is     appropriate size container under spout cap. Remove cap carefully. Allow bowl
overfilled      contents to drain into container. This will lower the water level in the bowl.
                Replace cap and return pour-out spout to stored position. DO NOT REMOVE
Odours          CASSETTE. Go inside the motorhome and turn the flush knob clockwise to
Toilet tissue   close valve blade. Now, the cassette may be removed following the normal
does not        removal and emptying procedure.
fit into
compartment.    Use proper amount of holding tank deodorant specified on bottle.
Soiled bowl
after flushing  Since some tissues are supplied on larger rolls, it may be necessary to use
No power to     some tissue before storing
add water to    into compartment.
toilet bowl
                Partially fill bowl to cover soiled portion of bowl. Next flush will dissolve waste.
Cassette        Tip: Leave valve blade open during use.
cannot be
removed         Check cassette safety sensor switch and fuse-holder for proper engagement
                and operation.
Valve blade     Note: Cassette has to be removed to reach switch and fuse.
mechanism       Insert cassette and try adding water to toilet bowl.
sticks or is    Toilet can be flushed manually. Add water. Add water to bowl from a separate
hard to open    container. Turn flush knob anti-clockwise to open valve blade. Turn clockwise
Major unit      to close valve blade.
malfunction
                Check for obstacles under retaining clip. Depress retaining clip several times
                to check operation. Remove cassette. Flush knob and valve blade in partial
                open position. Close valve blade by moving knob clockwise.

                CAUTION: If valve blade is open during cassette removal, severe
                damage to system can occur. Never force insertion or removal of the
                cassette tank.

                Spray light film of silicone on blade.

                Contact your original Motorhome Dealer.