The intelligent heat management system • D o not carry out any repair work or FITTED EQUIPMENT
operation in dual fuel mode and allow the modifications on the Truma CP plus control
Truma Combination boiler to prioritize the panel!
electric power source over your gas, which all
conserve your gas supply. • A defective Truma CP plus control panel may
only be repaired by the manufacturer or the
Control of Truma combi via Swift manufacturer’s service department.
Command
• Never use LP gas appliances when refuelling,
The Truma combi can also be controlled using in multi-storey car parks, in garages, or on
Swift Command. Please see details in the ferries. Switch off the LP gas appliance on
electrical section of this handbook for further the Truma CP plus control panel and make
details. sure that the LP gas appliance definitely
cannot be switched on via the Truma App.
While taking energy consumption and the
environment into account, consider using the Note:
Combi in summer mode (water heating only)
when room or space heating is not required, • If the power supply to the system has
but may be needed in the near future. This been interrupted, the time / time switch
ensures the appliance is held at the same must be reset.
temperature as the hot water setting chosen,
and this can reduce the time taken to provide • If a new or replacement appliance (heater,
warm air into the living area, when room or air conditioning system or iNet Box)
space heating is then selected. is connected to the bus system, the
procedure described in “Initial start-up”
Truma CP Plus must be repeated.
Digital Timer Control (when fitted)
• The ZUCB time switch can no longer
The Truma CP plus control panel is used to be used when the Combi CP plus ready
control and monitor a Combi CP plus ready heater is connected to the Truma CP plus
heater and/or a Truma air conditioning system. control panel.
The Truma CP plus serves as an interface for
operating connected appliances via Truma • If an iNET box is connected, the operation
App and iNet Box. (Trauma aftermarket option) of the CP plus controller will differ from
these instructions
The following air conditioning systems can be
operated with the Truma CP plus: 103
• Saphir compact
• Saphir comfort RC
• Aventa eco
• Aventa comfort
For further details on connecting and
controlling these items, and iNet contact your
dealer.
Safety instructions
• Operate the Truma CP plus control panel
only if it is in technically perfect condition.
• R epairs must be carried out immediately.
Only carry out repairs yourself if the solution
is described in the troubleshooting guide of