Select energy source Special fixtures in the mixed mode FITTED EQUIPMENT
• Select icon in menu bar (3) with rotary push • Interruption of the mains voltage 230V:
button.
The heating system switches automatically
• Change by tapping in the setting level. into gas mode. As soon as the 230V power
supply has been restored, the heating
• S elect desired energy source with rotary system automatically switches back to mixed
push button. mode.
• Tap the rotary push button to confirm the • F ault in combustion procedure (e.g. lack of
value. fuel).
The heating system switches automatically
into electrical mode. For the heater
to operate in mixed mode again, the
cause of the fault must be remedied and
acknowledged on the Truma CP plus control
panel. See “Fault” on page 114.
Symbol Operating mode Power type The heater automatically switches to the gas
mode. As soon as the 230 V power supply
a Gas Gas is reconnected, the heater automatically
switches back to the mixed mode.
b MIX 1 Gas + Electro
Special features in electric mode
c MIX 2 Gas + Electro
Combi Gas
d EL 1 Electro
• If the 230 V power supply is interrupted and
e EL 2 Electro the 12 V supply is switched on, a fault code
is shown on the display.
As soon as the heater is switched on (room
temperature, hot water level active), the • When the 230 V power supply has been
status line shows the energy type selected in restored, the heater is automatically started
the previous heating procedure. The factory with the existing settings. The fault code
setting is gas / diesel. goes off.